Mitsubishi Electric / Water-cooled VRF

Mitsubishi Electric · Water-cooled VRF

Water-cooled City Multi VRF.

WY heat pump and WR2 heat recovery VRF for high-rise, coastal and plant-constrained buildings — including buildings with an existing closed water loop that can be re-used. A strong option when replacing ageing central plant.

High-rise

Chiller replacement

Coastal sites

Hotels

Apartments

Mitsubishi Electric City Multi water-cooled VRF condensing unit
Image: Mitsubishi Electric

Key data

Capacity per unit22–150 kW
Indoor units per unit15 to 50
WR2 heat recoveryRefrigerant and water circuits
WR2 max. piping550–750 m (P200–P900)

The range

WY or WR2.

Both connect to a building’s closed water circuit. Condensing units give off no radiant heat, so they can sit in small plant rooms on each floor rather than on the roof.

WY-Series heat pump

PQHY-P200-900Y(S)LM-A. Water-source heat pump VRF from 22 to 150 kW, with 15 to 50 indoor units per condensing unit and individual or centralised control.

Mitsubishi Electric

WR2-Series heat recovery

PQRY-P200-900Y(S)LM-A. Double heat recovery — between indoor units on the refrigerant side and between condensing units on the water loop — for simultaneous heating and cooling.

Mitsubishi Electric

Re-using existing plant

Mitsubishi Electric states water-cooled VRF can connect to a building’s closed water circuit, including one from a previous chiller system — often the key to a staged, floor-by-floor replacement.

Air Theory

Selection & installation

The water loop decides the job.

In a replacement, the existing water side matters as much as the new VRF. We assess it before recommending a system.

  • Condition and capacity of the existing loop, pumps and heat rejection plant
  • Water treatment, strainers and flushing before connection
  • Cooling tower or dry cooler obligations reviewed with the owner
  • Floor-by-floor changeover planned around tenants
  • Loop pumps, valves and alarms integrated with the BMS
  • Refrigerant charge checked against AS/NZS 5149

Specifications

Manufacturer data.

From Mitsubishi Electric Australia product pages, checked 5 November 2026. Manufacturer data may change — confirm against the current data book before selection.

WY heat pumpWR2 heat recovery
Condensing unit modelsPQHY-P200-900Y(S)LM-APQRY-P200-900Y(S)LM-A
Capacity range22–150 kW22–150 kW
OperationCooling or heating (changeover)Simultaneous heating and cooling
Heat recovery—Refrigerant circuit and water loop
Indoor units per condensing unit15 to 5015 to 50
Max. refrigerant pipingRefer to data book550–750 m (P200–P900)
Water sourceClosed water circuitClosed water circuit

How to buy

Choose your route.

Projects & installation

Supply, installation and commissioning as part of a coordinated mechanical package.

Upgrades & business cases

Replacing existing plant? Start with the options, costs and payback.

Compare the range

See every Mitsubishi Electric system we supply and install.

Quotation

Need pricing for water-cooled VRF?

Send the drawings, the building and what you need. We’ll confirm the selection, supply and next steps.